The Hanna Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10 points resolution while professional instrumentation can cost hundreds of dollars and can be time-consuming to calibrate and maintain. The Checker® is both accurate and affordable.
- Description
- Specifications
- Documentation
- Additional information
- Test1
Description
Nitrification is the biological oxidation of ammonia (ammonium ion) into nitrite followed by the oxidation of the nitrites to nitrates. The first step of this 2-step process is carried out in an aquarium by nitrifying bacteria. During this quick process, the ammonium levels drop while the nitrite levels increase. Since nitrite is just as harmful as ammonia, nitrite levels should be maintained at immeasurable levels. A mature biological filter should be able to keep nitrite levels low. Also, if tap water is to be used in an aquarium, it is recommended that it be tested for phosphate, as well as silicate, ammonia, nitrate, nitrite, pH, and alkalinity.
The HI764 Checker® Handheld Colorimeter bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate, while professional instrumentation can cost hundreds of dollars and can be time-consuming to calibrate and maintain. Hanna Checker®’s are accurate, affordable and easy to use.
To begin measurements, first, zero the instrument with your water sample. Next, add the reagent. Last, place the vial into the Checker®, press the button and read the results. It’s that easy.
The contoured style of these Checker®’s fit in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.
SKU | HI764 |
Name | Marine Nitrite Ultra Low-Range Checker® HC – HI764 |
Nitrite Range | 0 to 200 ppb |
Nitrite Resolution | 1 ppb |
Nitrite Accuracy | ±10 ppb ±4% of reading |
Nitrite Method | adaptation of the EPA Diazotization method 354.1. |
Photometer/Colorimeter Light Source | LED @ 525 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after two minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”) |
Additional information
Weight | 0.064 kg |
---|---|
Dimensions | 8.6 × 6.1 × 3.75 cm |