Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

Author - tony

Cap Dauphin Fishermen’s Coop

Cap Dauphin Fishermen's Coop Institution: Cap Dauphin Fishermen's Coop Location: Grosse Île, Iles de la Madeleine, Québec, Canada Contact: Mme. Ruth Taker Habitat: Seawater Type of rearing unit: THREE ECO LOBSTER-CONDOS FOR FOR PURGING LOBSTER AND  MID TERN STORAGE   Unit description: Modification of three existing holding system to add a drip system. Chilling system to bring temperature down to 3°C (+0.2°C) with titanium heat exchanger; Oxygen monitoring and improved air diffusion with pure oxygen injection for both pounds. Electronic controller system : 3 DO probe, 3 temperature probe, 3...

Lelièvre, Lelièvre & Lemoignan

Lelièvre, Lelièvre & Lemoignan Institution: Lelièvre, Lelièvre & Lemoignan Location: Sainte-Thérèse-de-Gaspé, Québec, Canada Contact: Mr. Roch Lelièvre Habitat: Saltwater Type of rearing unit: ECO LOBSTER-CONDOS TWO FOR FOR PURGING 52,000 LB OF LOBSTER AND ONE FOR PURGING AND MID TERN STORAGE   Unit description: Modification of two existing holding system to add a drip system (capacity of 26 tones). RAS Modules with drip system for total capacity of 30 tons; Biofiltration media positively charged with high affinity for attracting gram-ve bacteria such as nitrifyers. Biofilter self-cleaning and pre-activated...

Université Laval – Tide Simulator

Université Laval -  Tide Simulator Institution: Location: Sainte-Foy, Québec, CANADA Contact: Dr. Julie Turgeon Equipment: Two Multi-tank systems custom-adapted to simulate the gradual fluctuations in salinity associated with the tides. Université Laval - Tide Simulator Species: Vertebrates & invertebrates; Habitats: Fresh water, brackish & marine; Temperature: 7° to 30° C; Description: Each closed circuit Multi-tank holding REBF system contains 40 holding tanks (thirty 2.8 liter tanks and ten 9 liter tanks). Simple to install by client; On multi-tank unit operate from 0 to 15 PSU and the other operate from 15 to...

University of Saskatchewan – Multi-Stress System

University of Saskatchewan  - Multi-Stress System Institution: Location: Saskatoon, Saskatchewan, Canada Contact: Dr. Monique Dube Equipment: Four Multi-Stressor Units Habitats: Fresh water & Seawater; Temperature:1 20° to 30° C; Description: Parameters Specification Filtration module flow (LPM) 15 Water turnover per hour in tanks 10 System temperature (°C) 20 – 30 Room temperature  (°C) 20 Recommended water flushing rate (% of the total unit volume per day ) 164 Filtration module volume per system (L) 20 Actual habitat volume per system (L) 90 (with 10 x 9-L tanks) Total volume per system (L) 110 Monitoring & Control Oxygen, Temperature, Water make-up. Water make-up flow (LPM) (volume pumped by each...

Universitad Autonomo Mexico – Respirometer

Universitad Autonomo Mexico - Respirometer Institution: Location: Sisal, Hunucma, Yucatán, México Contact: Dr. Carlos Rosas Vaquez Universitad Autonomo Mexico - Respirometer Equipment: Respirometer Multi-Stressor Unit Habitats: Fresh water & Seawater; Temperature:1 8° to 35° C; Description: Parameters Unit Details 1 Electricity x 120 volts 60 HZ 1 Ph 15 Amp Electrical plug x US Habitat Habitat non insulated x Water outlet x 10 outlets Air outlet x 10 outlets Position water vs air outlet  (special request) x Water outlets in front of the air outlets Flowmeter (special request) x Replace with one smaller flowmeter (25-250 L/h) Temperature control x 8-35°C ± 0.3°C (special request) TECO 1000 Chilling system x Independent 500 w heater x Static, dynamic & cyclic x Maximum...

Universitad Autonomo Mexico – Multi-Stress System

Universitad Autonomo Mexico - Multi-Stress System Institution: Location: Sisal, Hunucma, Yucatán, México Contact: Dr. Carlos Rosas Vaquez Equipment: Four Multi-Stressor Units Habitats: Fresh water & Seawater; Temperature:1 15° to 35° C; Description: Parameter Specification Number of 1-L tanks (1.5L) Total volume per unit 14 tanks 21L Number of 3-L tanks (2,8-L) Total volume per unit 12 tanks 34L Number of 9-L tanks (9.35-L) Total volume per unit 6 tanks 56L Total volume per unit with 9-L tanks (L) 56L + 22L= 78 (22L is the water within Filtration Module, pumps & plumbing) Total volume par unit with 3-L tanks 34L+22L =56 L Total...

Fisheries and Oceans Canada – Multi-Stress System

Fisheries and Oceans Canada - Multi-Stress System Institution: Location: Winnipeg, Manitoba, Canada Contact: Dr. David Deslauriers  Central & Arctic Region, Freshwater Institute Arctic and Aquatic Research Division Equipment: Three Multi-Stressor Units Habitats: Fresh water & Seawater; Temperature:1 0.1° to 20° C; Description: Parameters Units Details 1 2 3 General Habitat insulated with sliding door x x x Photoperiod control (300 Lux @ 100%) x x x Manual, Astral & annual Rearing tanks x x x 6 x 9-L tanks, with lid and baffle Temperature control x x x 0.1-20°C ± 0.2°C in seawater. Central glycol Chilling system x Central glycol system on an additional 24’’x 48’’ shelving. Independent 500 w heater No. heater. Passive heat...

Université de Moncton – Multi-Stress System

Université de Moncton- Multi-Stress System Institution: Location: Moncton, New-Brunswick, Canada Contact: Dr.Simon Lamarre Equipment: Three Multi-Stressor Units Habitats: Fresh water & Seawater; Temperature:1 1° to 30° C; Description: Control of water temperature between 1°C and 30°C; Custom-build glycol chilled systems, chilling and heating water at a very high rate (10°C/h). Generate hyperoxic conditions up to 110% saturation; Generate hypoxic conditions down to 30% saturation; While under hypoxic conditions: an automatic mix of air, oxygen and nitrogen provides constant degasing action, protecting the animals from buildup of CO2 gas; your animal...

Memorial University – Multi-Stress System

Memorial University- Multi-Stress System Institution: Location: St-John's, Newfoundland & Labrador, Canada Contact: Dr. Annie Mercier Equipment: Two Multi-Stressor Units Habitats: Fresh water & Seawater; Temperature: 5° to 30° C; Description: Control of water temperature between 5°C and 30°C; Generate hyperoxic conditions up to 110% saturation; Generate hypoxic conditions down to 30% saturation; While under hypoxic conditions: an automatic mix of air, oxygen and nitrogen provides constant degasing action, protecting the animals from buildup of CO2 gas; your animal are protected against accidental drop of dissolved oxygen below the...

University of Southampton- Two Multi-Stress Units

University of Southampton- Three Multi-Stress Units Institution: Location: Southampton, UK Contact: Dr. Jasmin Godbold Habitat: Freshwater & Seawater Type of rearing unit: University of Southampton- Three Multi-Stress Units Unit description: Parameters Unit Details 1 2 Electricity x x 220 volts 50 HZ 1 Ph Electrical plug x x British Temperature control x x 4-35°C ± 0.3°C Habitat insulated with sliding doors x x TECO 2000 Chilling system x x Independent 500 w heater x x Static, dynamic & cyclic x x See descriptions below Maximum rate of change: x x -3.5 & +3.7°C /hour Precision x x 0.3°C Water make-up x x Max 100% du volume Water pressure regulator 1 Dissolved oxygen x >2mg/L (3-4 mg/L). Static x Air supplied on site x 1 CFM @ 35 PSI per unit Nitrogen supplied on site x 0.8 @ 35 PSI per unit Air flow...